If you order a customisable Dedicated Server or Bare Metal Server with hardware RAID and additional storage, a Level 1 hardware RAID is only created for the server’s primary storage.
You must set up a separate hardware RAID for the additional storage in the following case:
You have ordered a customisable Dedicated Server or Bare Metal Server with hardware RAID that uses HDD storage as the primary storage and HDD or SSD storage as additional storage.
You must create a separate software RAID for the additional storage in the following cases:
You have ordered a customisable Dedicated Server or Bare Metal Server with hardware RAID that uses HDD storage as the primary storage and NVMe storage as additional storage.
You have ordered a customisable Dedicated Server or Bare Metal Server with hardware RAID that uses NVMe storage as the primary storage and HDD or SSD storage as additional storage.
This article explains the advantages and disadvantages of the main RAID levels and the criteria you should consider when selecting the appropriate RAID level. It also explains how to create a separate Level 1 hardware RAID on a customisable Dedicated Server or Bare Metal Server with hardware RAID that uses HDD storage as the primary storage and HDD or SSD storage as additional storage.
Depending on your use case, you can also set up RAID systems with other RAID levels for your storage devices.
Note
You can find instructions on creating a software RAID for a customisable Dedicated Server or Bare Metal Server in the following article: Creating an additional software RAID (Linux)
Please Note
This article assumes that you have good knowledge of Linux server administration. The commands in this article must be adapted to your server’s configuration. Check and adjust them before you partition and format the storage devices and before you create the additional hardware RAID. Otherwise, data loss may occur.
Criteria for selecting the appropriate RAID level
RAID systems offer greater data security, higher speeds, or both. However, they are no substitute for regular backups. You should therefore back up your data regularly to prevent data loss.
You can determine which RAID level is suitable for your server by answering the following questions:
Which operating system is used on the server, and which RAID levels does it support?
What storage capacity is required? How much of the installed storage capacity should be usable?
What are the requirements for read and write speeds?
What are the requirements for data security?
An overview of the main RAID levels
The following table lists the main RAID levels, along with their advantages and disadvantages:
| RAID 0 | RAID 1 | RAID 5 | RAID 6 | RAID 10 (1+0) | |
|---|---|---|---|---|---|
| Minimum number of storage devices (HDD, SSD, or NVMe) | 2 | 2 | 3 | 4 | 4 |
| Method used | Striping | Mirroring | Striping and parity | Striping and double parity | Striping of mirrored data |
| Fault tolerance | none | failure of one drive | failure of one drive | failure of two drives | failure of one drive per sub-array |
| Capacity utilisation |
100% Number of storage devices × capacity |
50% Capacity of one storage device |
67% (Number of storage devices – 1) × capacity |
50% (Number of storage devices – 2) × capacity |
50% (Number of storage devices / 2) × capacity |
| Write speed | very high | low | medium | low | medium |
| Read speed | very high | medium | high | high | very high |
| Advantages |
Higher bandwidth than single drives More input/output operations per second than single drives |
Full redundancy Data security and speed can optionally be increased with a suitable controller or software |
Increased reliability through parity Good price-performance ratio in terms of redundancy and storage efficiency |
High reliability thanks to double parity Slightly improved read throughput compared to single drives |
Increased read speed compared to single drives Increased reliability of the storage devices used |
| Disadvantages |
Higher probability of failure than single drives No redundancy: if a storage device fails, a large proportion of the data is lost |
The storage capacity of the array is at most as large as the capacity of the smallest storage device High cost |
Write speed is reduced compared to single drives Only part of the total storage capacity of the storage devices can be used |
Write speed is significantly reduced compared to single drives Only part of the total storage capacity can be used, particularly in smaller arrays |
Significantly reduced maximum available storage capacity If two storage devices in the same sub-array fail, the entire array fails |
Determining the hardware controller type and displaying hardware information
To check which hardware controller is installed in your server, you can use the lshw program. It displays detailed information about the hardware components.
Installing lshw
Ubuntu and Debian
sudo apt update
sudo apt install lshw
AlmaLinux 9, AlmaLinux 10, Rocky Linux 9, and Rocky Linux 10
dnf install lshw
Displaying hardware information with lshw
To display a summary of the hardware information, enter the following command:
lshw -short
To save the hardware information to a text file, enter the following command:
lshw > lshw_output.txt
Creating a separate Level 1 hardware RAID for the additional storage devices
These example instructions were created for a customisable Dedicated Server with a Broadcom RAID controller. The commands may differ depending on the hardware controller used.
If you are using a different hardware controller, the commands for listing the volumes and creating a new RAID array will differ. In this case, you can find the required commands in the manufacturer’s documentation.
Caution
Before creating the RAID 1 array, make sure that you are using two identical storage devices of the same size.
To check which storage devices are installed in your server, enter the following command:
[root@90398B0 ~]# storcli64 /c0/eall/sall show
This command displays all storage devices that are managed by the hardware controller. Information such as the following is displayed:
[root@90398B0 ~]# storcli64 /c0/eall/sall show
CLI Version = 007.2203.0000.0000 May 11, 2022
Operating system = Linux 3.10.0-1160.83.1.el7.x86_64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================
----------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------
68:0 1 Onln 0 3.637 TB SATA HDD N N 512B HGST HUS726T4TALA6L4 U -
68:1 0 Onln 0 3.637 TB SATA HDD N N 512B HGST HUS726T4TALA6L4 U -
68:2 2 UGood - 893.750 GB SATA SSD Y N 512B SAMSUNG MZ7L3960HCJR-00A07 U -
68:3 3 UGood - 893.750 GB SATA SSD Y N 512B SAMSUNG MZ7L3960HCJR-00A07 U -
----------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self-Encrypting Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=RebuildMake a note of the EID:Slt values of the storage devices with the status UGood (in this example, 68:2 and 68:3).
To use the additional storage devices, create a new RAID array with RAID level 1 for them. This allows you to use the additional storage space independently of the existing RAID array. To do this, adapt the command below to the information displayed in step 1 and then enter it. Replace RAID_NAME with a name for the RAID and, if necessary, replace the drive designations 68:2-3. In the command, /c0 refers to the first RAID controller and vd stands for virtual drive (the logical volume).
storcli64 /c0 add vd type=raid1 name=RAID_NAME drives=68:2-3
Example:
storcli64 /c0 add vd type=raid1 name=DATA_RAID1 drives=68:2-3
A message is then displayed confirming that the additional RAID has been created:
[root@90398B0 ~]# storcli64 /c0 add vd type=raid1 name=DATA_RAID1 drives=68:2-3
CLI Version = 007.2203.0000.0000 May 11, 2022
Operating system = Linux 3.10.0-1160.83.1.el7.x86_64
Controller = 0
Status = Success
Description = Add VD Succeeded.To check whether the new RAID array has been recognised, enter the following command:
storcli64 /c0/eall/sall show
Information such as the following is displayed:
[root@90398B0 ~]# storcli64 /c0/eall/sall show
CLI Version = 007.2203.0000.0000 May 11, 2022
Operating system = Linux 3.10.0-1160.83.1.el7.x86_64
Controller = 0
Status = Success
Description = Show Drive Information Succeeded.
Drive Information :
=================
----------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------------------
68:0 1 Onln 0 3.637 TB SATA HDD N N 512B HGST HUS726T4TALA6L4 U -
68:1 0 Onln 0 3.637 TB SATA HDD N N 512B HGST HUS726T4TALA6L4 U -
68:2 2 Onln 1 893.750 GB SATA SSD Y N 512B SAMSUNG MZ7L3960HCJR-00A07 U -
68:3 3 Onln 1 893.750 GB SATA SSD Y N 512B SAMSUNG MZ7L3960HCJR-00A07 U -
----------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self-Encrypting Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=RebuildThe storage devices should now have the status Onln (Online) and be assigned to a drive group (DG).
To list the existing disks and partitions, enter the following command:
root@90398B0:~# fdisk -l
The fdisk program is a command-line tool for partitioning disks. You can use it to view, create, and delete partitions.
A new device whose size matches your new RAID should now be displayed. In this example, this is the device /dev/sdb:
root@90398B0:~# fdisk -l
Disk /dev/sda: 3.7 TiB, 4000225165312 bytes, 7812939776 sectors
Disk model: MR9440-8i
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 512 bytes
I/O size (minimum/optimal): 65536 bytes / 65536 bytes
Disk label type: gpt
Disk identifier: 1FEE5173-7F6E-421D-B323-E11E2C5CBECB
Device Start End Sectors Size Type
/dev/sda1 2048 1048575 1046528 511M EFI System
/dev/sda2 1048576 3905535 2856960 1.4G Linux RAID
/dev/sda3 3905536 11718655 7813120 3.7G Linux RAID
/dev/sda4 11718656 7812937727 7801219072 3.6T Linux RAID
Disk /dev/sdb: 893.8 GiB, 959656755200 bytes, 1874329600 sectors
Disk model: MR9440-8i
Units: sectors of 1 * 512 = 512 bytes
Sector size (logical/physical): 512 bytes / 4096 bytes
I/O size (minimum/optimal): 65536 bytes / 65536 bytes
Disk label type: gpt
Disk identifier: B1590B72-4F09-4677-80A4-A1D8C6CB218FMake a note of the device name of the new RAID array (in this example, /dev/sdb).
If you want to use the XFS file system, create the directory /xfsdrive. If you want to use the ext4 file system, create the directory /ext4drive. To do this, enter the matching command:
XFS
mkdir /xfsdrive
ext4
mkdir /ext4drive
To partition the additional RAID array, adapt the commands below and then enter them. The -a opt option specifies that the optimal alignment mode is used. The mkpart primary command creates a new primary partition. The values 0% and 100% specify the start and end points of the new partition, so the partition occupies all the available space.
Create a GPT partition table:
parted /dev/ADDITIONAL-RAID-ARRAY mklabel gpt -a opt
Create a partition that uses 100% of the space:
parted /dev/ADDITIONAL-RAID-ARRAY mkpart primary 0% 100%
Example:
parted /dev/sdb mklabel gpt -a opt
parted /dev/sdb mkpart primary 0% 100%To make sure that the kernel recognises the new partition table, enter the command below. It instructs the kernel to re-read the partition table and displays a summary of the partitions.
partprobe -s
To format the partition with the XFS or ext4 file system, adapt the matching command below and then enter it. Make sure that you format the partition, not the entire device:
XFS
mkfs.xfs /dev/PARTITION
Example:
root@90398B0:~# mkfs.xfs /dev/sdb1
ext4
mkfs -t ext4 /dev/PARTITION
Example:
root@90398B0:~# mkfs -t ext4 /dev/sdb1
To mount the partition, adapt the matching command below and then enter it. Make sure that the directory already exists.
XFS
mount /dev/PARTITION /xfsdrive
Example:
mount /dev/sdb1 /xfsdrive
ext4
mount /dev/PARTITION /ext4drive
Example:
mount /dev/sdb1 /ext4drive
To check that the partition is mounted as /xfsdrive or /ext4drive, enter the matching command:
XFS
grep xfsdrive /proc/mounts
ext4
grep ext4drive /proc/mounts
To determine the UUID of the new partition, enter the following command:
blkid /dev/PARTITION
Example:
blkid /dev/sdb1
To mount the partition automatically at boot time, add it to the /etc/fstab file. To do this, adapt the command below and then enter it:
echo 'UUID=YOUR-UUID /MOUNT-DIRECTORY FILE-SYSTEM defaults 0 0' | sudo tee -a /etc/fstab
Examples:
ext4
echo 'UUID=YOUR-UUID /ext4drive ext4 defaults 0 0' | sudo tee -a /etc/fstab
XFS
echo 'UUID=YOUR-UUID /xfsdrive xfs defaults 0 0' | sudo tee -a /etc/fstab
To check the /etc/fstab file for errors, enter the following command:
mount -a
To check the entries in the /etc/fstab file, enter the following command:
cat /etc/fstab
To check the available storage space, enter the following command:
df -h
Restart the system.
To check whether the RAID has been mounted, enter the following command:
mount
Troubleshooting
If the command storcli64 /c0/eall/sall show returns the status Success after you have created the RAID array, but the RAID does not appear as a new drive when you enter the command fdisk -l, the Linux kernel has not yet rescanned the storage bus (SCSI). In this case, force a rescan of the SCSI bus with the following command:
for host in /sys/class/scsi_host/*; do echo "- - -" > ${host}/scan; done
Wait a few seconds and check again with lsblk or fdisk -l. The drive should now appear. Alternatively, restarting the server with the reboot command usually helps.